Electrochemical analyzer/workstation
5.0
Read 200 reviewsThis Model of Electrochemical analyzer/workstation is designed for general purpose electrochemical measurements. The figure below shows the block diagram of the instrument. The system contains a fast digital function generator, a direct digital synthesizer for high frequency ac waveforms, high speed
17 people are viewing this right now
This Model of Electrochemical analyzer/workstation is designed for general purpose electrochemical measurements. The figure below shows the block diagram of the instrument. The system contains a fast digital function generator, a direct digital synthesizer for high frequency ac waveforms, high speed dual-channel data acquisition circuitry, a potentiostat, and a galvanostat (available only in select models). The potential control range is ±10 V and the current range is ±250 mA. The instrument is capable of measuring current down to picoamperes. With the CHI200B Picoamp Booster and Faraday Cage, currents at sub-picoamperes can be measured. The instrument is very fast. The function generator can update at a 10 MHz rate. Two high speed and high resolution data acquisition channels allow both current and potential (or an external voltage signal) to be sampled simultaneously at a rate of 1 MHz, with 16-bit resolution. The instrument offers a very wide dynamic range of experimental time scales. For instance, the scan rate in cyclic voltammetry can be up to 1000 V/s with a 0.1 mV potential increment or 5000 V/s with a 1 mV potential increment. The potentiostat / galvanostat uses a 4-electrode configuration, allowing it to be used for liquid/liquid interface measurements, and eliminating the effect of the contact resistance of connectors and relays for high current measurements. The data acquisition systems also allow an external input signal (such as spectroscopic) to be recorded simultaneously during an electrochemical measurement.
Potentiostat
Zero resistance ammeter
2- or 3- or 4-electrode configuration
Floating (isolated from earth) or earth ground
Maximum potential: ±10 V
Maximum current: ±250 mA continuous, ±350 mA peak
Compliance Voltage: ±13 V
Potentiostat rise time: < 1 μs, 0.8 μs typical
Applied potential ranges (volts): ±0.01, ±0.05, ±0.1, ±0.65, ±3.276, ±6.553, ±10
Applied potential resolution: 0.0015% of potential range
Applied potential accuracy: ±1 mV, ±0.01% of scale
Applied potential noise: < 10 μV rms
Measured current range: ±10 pA to ±0.25 A in 12 ranges
Measured current resolution: 0.0015% of current range, minimum 0.3 fA
Current measurement accuracy: 0.2% if current range >=1e-6 A/V, 1% otherwise
Input bias current: < 20 pA
Galvanostat
Galvanostat applied current range: 3 nA - 250 mA
Applied current accuracy: 20 pA ±0.2% if > 3e-7A, ±1% otherwise
Applied current resolution: 0.03% of applied current range
Measured potential range (volts): ±0.025, ±0.1, ±0.25, ±1, ±2.5, ±10
Measured potential resolution: 0.0015% of measured range
Electrometer
Reference electrode input impedance: 1x1012 ohm
Reference electrode input bandwidth: 10 MHz
Reference electrode input bias current: <= 10 pA @ 25°C
Waveform Generation and Data Acquisition
Fast waveform update: 10 MHz @ 16-bit
Fast data acquisition: dual channel 16-bit ADC, 1,000,000 samples/sec simultaneously
External signal recording channel at maximum 1 MHz sampling rate
Experimental Parameters
CV and LSV scan rate: 0.000001 to 10,000 V/s
Potential increment during scan: 0.1 mV @ 1,000 V/s
CA and CC pulse width: 0.0001 to 1000 sec
CA and CC minimum sample interval: 1 μs
True integrator for CC
DPV and NPV pulse width: 0.001 to 10 sec
SWV frequency: 1 Hz to 100 kHz
i-t sample interval: minimum 1 μs
ACV frequency: 0.1 Hz to 10 kHz
SHACV frequency: 0.1 Hz to 5 kHz
FTACV frequency: 0.1 Hz to 50 Hz, simultaneously acquire 1st, 2nd, 3rd, 4th, 5th, and 6th harmonics ACV data
IMP frequency: 0.00001 Hz to 1 MHz
IMP amplitude: 0.00001 V to 0.7 V rms