High rate battery tester system

High rate battery tester system

Channels No.: 1-8 channels of the whole machine
Work flow control mode: independent control for each channel
Test parameters: current, voltage, internal resistance, temperature, external voltage test signal
Charging mode: constant current, constant voltage, constant power charging
Charging cut-off conditions: voltage, current, time, capacity
Discharge mode: constant current, constant voltage, constant power, constant resistance discharge
Discharge cut-off conditions: voltage, current, time, capacity
Extended function: multi-channel parallel use
Protection function: over voltage, under voltage, over current, under current, over capacity protection
Reverse connection protection
Power failure protection, data breakpoint recovery
Process setting: up to 64 steps and 1999 cycles can be set
Current establishment time: ≤1-20ms
Sampling inspection cycle: ≤100-500ms
Minimum data recording frequency: ≤1-100ms
Software: It can record voltage, current, time, capacity, internal resistance, temperature and other data, has powerful data processing functions, and provides multiple curve modes
Can output and generate files in text, EXCEL, WORD or MDB database format.
Current range(A) ≤5A,10-30A,60A-300A,500A-3000A
Voltage Range(V) 5V,15V,20V,60V
Working Model Constant current charge/discharge, constant voltage charge, constant current constant voltage charge, constant power charge/discharge, constant resistance discharge, DCIR、 rate charge/discharge, static
Restrictive condition About 20 kinds of time, voltage, current, capacity ,△V etc
Protection conditions Overpressure, underpressure, overflow, underflow, overcharge capacity, over discharge capacity, etc
Channels 1-8
 Voltage accuracy 0.05%RD±0.05%FS
Current accuracy 0.05%RD±0.05%FS
Temperature accuracy ±1℃
Time range 0-30000 minutes of any setting, the unit of time is min.s optional
Time accuracy ≤±0.1%
 temperature measurement K thermocouple, measuring range-40~200℃