GELON LIB GROUP   EN | 中文
Tel:+8618669965529    Email:ekain@libgroup.net

Home > Product > Battery Testing & Analyzing Instruments  > Battery chemical performance inspection > Recyle charge and discharge machine

Battery grading and formation tester systerm for production

Battery grading and formation tester systerm for production

Number of equipment channels: 256/512 channels in total
Work flow control mode: whole cabinet control
Charging mode: constant current, constant voltage
Charging cut-off conditions: voltage, current, time, capacity
Discharge mode: constant current
Discharge cut-off conditions: voltage, time, capacity
Protection function: over voltage, under voltage, over current, under current, over capacity protection, reverse connection protection, power failure protection, data break point recovery
Process setting: up to 32 steps and 256 cycles can be set
Sampling inspection cycle: ≤8s
Minimum data recording frequency: ≤8s
Sorting: sorting under various conditions (capacity, time, open circuit voltage, discharge platform, etc.)
Multiple methods (continuous capacity, minimum capacity, capacity difference, etc.) for sorting
Software: can record voltage, current, time, capacity and other data, has powerful data processing functions, and provides multiple curve modes
Can output and generate files in text, EXCEL, WORD or MDB database format
Voltage measurement range: 0-5V, resolution 1mV
Battery voltage range: charging 0-4.5V; discharging 4.5-2V
Constant voltage range: 2-4.5V
Voltage accuracy: ±(0.1%RD+0.1%FS)
Current range: charging 0.01-1A/2A/3A; discharging 0.01-1A/2A/3A, resolution 1mA
Current accuracy: ±(0.1%RD+0.1%FS)
Time range: arbitrarily set within 0-30000 minutes, the time unit is min
Time accuracy: ≤±0.1%
Fixture form: four-wire method fixture
Support battery height: 10~80mm, stepless adjustment
Fixture spacing: 35mm